Vivak Technical Data
Typical values
|
Units
|
Test
method
|
|
Physical |
|
|
|
Density |
1.27
|
g/cm³
|
DIN
53479
|
Moisture absorption: |
|
|
|
- 23°C, 24h immersion (3 mm) |
0.2
|
%
|
|
Index of refraction n D at 20°C |
1.57
|
|
DIN
53491
|
Light transmittance (2 mm sheet) |
88
|
%
|
DIN
5036
|
Mechanical |
|
|
|
Tensile stress at yield |
50
|
N/mm²
|
DIN
53455 (1)
|
Elongation at yield |
5
|
%
|
DIN
53455 (1)
|
Tensile strength |
26
|
N/mm²
|
DIN
53455 (1)
|
Elongation at break |
>100
|
%
|
DIN
53455 (1)
|
Tensile modulus of elasticity |
2050
|
N/mm²
|
DIN
53457 (2)
|
Limiting flexural stress |
77-83
|
N/mm²
|
DIN
53452
|
Impact strength: |
|
|
|
- Charpy unnotched |
no
break
|
J/m²
|
DIN
53453
|
- Charpy notched |
16
|
J/m²
|
DIN
53453
|
- Izod notched (4 mm) |
90
|
J/m
|
ASTM
D256
|
Instrumented impact (4 mm) at F max |
28
|
J
|
ASTM
D3763
|
Rockwell hardness |
R104-R117
|
rating
|
ASTM
D785
|
Thermal |
|
|
|
Glass transition temperature |
81
|
°C
|
|
Thermal conductivity (l) |
0.32
|
W/m°C
|
DIN
52612
|
Coeff. of linear thermal expansion |
0.050
|
mm/m°C
|
|
Heat deflection temperature under load acc. to SO/R75 |
DIN
53461
|
||
- method A: 1.81 N/mm 2 |
63
|
°C
|
|
- method B: 0.45 N/mm 2 |
70
|
°C
|
|
Max. service temperature in air (3) |
65
|
°C
|
|
Min. service temperature |
-40
|
°C
|
|
Electrical |
|
|
|
Dielectric strength (4) |
20
|
Kv/mm
|
IEC
243-1
|
Volume resistivity |
1015
|
Ohm.cm
|
DIN
53482
|
Surface resistivity |
1016
|
Ohm
|
DIN
53482
|
Dielectric constant at 10³ Hz |
2.6
|
-
|
DIN
53483
|
Dielectric constant at 106 Hz |
2.4
|
-
|
DIN
53483
|
Dissipation factor at 10³ Hz |
0.005
|
-
|
DIN
53483
|
Dissipation factor at 106 Hz |
0.020
|
-
|
DIN
53483
|
Flame |
|
|
|
Oxygen index |
26
|
%
|
ASTM
D2863
|
Flammability (3 mm sheet) |
V-2
(6)
|
rating
|
UL 94
|
Glow wire test (2 & 3 mm) |
850
|
°C
|
IEC695-2-1
|
Germany |
|
|
|
- 0.5 to 8 mm sheet |
B1
|
rating
|
DIN
4102/part1
|
- 4 mm sheet |
S4/SR2/ST1
|
rating
|
DIN
5510 DIN
|
- 5 & 6 mm sheet |
S4/SR2/ST2
|
rating
|
5510
|