73A GP | ||||
Physical | Nominal Values | Test | ||
Specific Gravity | 0.97 - | ASTM D792 | ||
Elastomers | Nominal Values | Test | ||
Tensile Stress @ 100% | 522 psi | ASTM D412 | ||
Tensile Str @ Break Elast | 1230 psi | ASTM D412 | ||
Elongation @ Break Elast | 460% | ASTM D412 | ||
Tear Strength | 160 lb/in | ASTM D624 | ||
Tear Strength Temp | 73.4 °F | |||
Compression Set | 24% | ASTM D395 | ||
Compression Set Temp | 73.4 °F | |||
Hardness | Nominal Values | Test | ||
Durometer Hardness A | 73 - | ASTM D2240 | ||
Durometer Scale | A Scale - | |||
Durometer Test Thickness | 0.118 in | |||
Thermal | Nominal Values | Test | ||
Brittle Temperature | - 76 °F | ASTM D746 | ||
Electrical | Nominal Values | Test | ||
Dielectric Strength | 498 V/mil | ASTM D149 | ||
Dielectric Str. Thickness | 125 mil | |||
Dielectric Constant | 2.3 - | ASTM D150 | ||
Arc Resistance | 90 s | ASTM D495 | ||
Arc Resistance Thickness | 0.125 in | |||
Flammable | Nominal Values | Test | ||
Flame Rating - UL, HB | 0.0398 in | UL 94 | ||
UL 746 | Nominal Values | Test | ||
Rel Temp Indx Mech w/olmp | 203 °F | UL 746 | ||
RTI Mech w/olmp Thick | 0.125 in | |||
Rel Temp Indx Mech w/lmp | 158 °F | UL 746 | ||
RTI Mech w/lmp Thick | 0.125 in | |||
Rel Temp Indx Elect | 194 °F | UL 746 | ||
RTI Elect Thick | 0.0398 in | |||
Comparative Track Index | 600 V | UL 746 | ||
Compar Track Index Thick | 0.125 in | |||
High Volt Arc Track Rate | 0.689 in/min | UL 746 | ||
High Volt Track Rate Thck | 0.0398 in | |||
Hot Wire Ignition | 22.5 s | UL 746 | ||
Hot Wire Ignition Thick | 0.0618 in | |||
High Ampere Arc Ignition | 120 - | UL 746 | ||
High Amp Arc lgn Thick | 0.0398 in |